Ignition Circuit - Gilera 2008 MSS Nexus User Manual

Table of Contents

Advertisement

MSS Nexus 300 i.e. E3 ( 2008)
3-flash code
Diagnostic code - 1 flash
The one-flash code indicates a system where the
serial line is not present or is not detected. Check
the Immobilizer aerial wiring and change it if nec-
essary.
Diagnostic code - 2 flashes
A two-flash code shows a system where the con-
trol unit does not show the transponder signal. This
might depend on the inefficiency of the immobiliser
aerial or the transponder.
Turn the switch to ON using several keys: if the
code is repeated even with the Master key, check
the aerial wiring and change it if necessary. If this
is not the case, replace the defective key and/or
reprogram the control unit. Replace the control unit
if the problem continues.
Diagnostic code - 3 flashes
A three-flash code indicates a system where the
control unit does not recognise the key. Turn the
switch to ON using several keys: if the error code
is repeated even with the Master key, replace the
control unit. If this is not the case, perform a re-
programming.