Ignition Circuit; Diagnostic Code - 3 Flashes; No Spark Plug - Gilera GP 800 i.e. Service Station Manual

Table of Contents

Advertisement

Electrical system
YES go to 5 NO go to 4
4 - Restore the connection and check the presence
of the code
5 - Disconnect the aerial connector and check con-
tinuity (8 ± 2 W).
YES go to 7 NO go to 6
6 - Replace the aerial.
7 - Check the proper position of the aerial.
YES go to 9 NO go to 8
8 - Place it in proper position
9 - Replace the decoder and check the presence of the code

Diagnostic code - 3 flashes

Code no. 3 denotes a system where the decoder
perceives a transponder not provided for by pro-
gramming.
- Start-up disabled
- Injection telltale light on, steady
1- Check whether the code is still displayed using the master key
YES go to 3 NO go to 2
2 - Program again using all service keys
3 - Check that all components (keys - decoder - control unit) are properly matched.
YES go to 5 NO go to 4
4 - Restore
5 - Replace decoders and control unit. Program the components again.

Ignition circuit

No spark plug

HV coil primary check
WARNING
ALL CONTINUITY TESTS MUST BE CARRIED OUT WITH THE CORRESPONDING CONNECTORS
DISCONNECTED.
ELE SYS - 32
GP 800 i.e.