IBM System x3350 Type 4192 Problem Determination And Service Manual page 165

Type 4192 and 4193
Hide thumbs Also See for System x3350 Type 4192:
Table of Contents

Advertisement

2. To view the light path diagnostics panel, press the release latch on the front of
the light path operator information panel to the left; then, slide it forward. This
reveals the light path diagnostics panel. Lit LEDs on this panel indicate the type
of error that has occurred.
The following illustration shows the light path diagnostics panel.
OVER SPEC
REMIND
Look at the system service label on the top of the server, which gives an
overview of internal components that correspond to the LEDs on the light path
diagnostics panel. This information and the information in "Light path diagnostics
LEDs" on page 148 can often provide enough information to diagnose the error.
3. Remove the server cover and look inside the server for lit LEDs. A lit LED on or
beside a component identifies the component that is causing the error.
The following illustration shows the LEDs on the system board.
Light Path
Diagnostics
PS1
PS2
VRM
CPU
CNFG
MEM
NMI
S ERR
SP
DASD
RAID
FAN
TEMP
BRD
PCI
147
Chapter 5. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3350 type 4193

Table of Contents