Inverter Gate Solenoid Adjustment - Ricoh FT7060 Field Service Manual

Table of Contents

Advertisement

12 July '86

38. Inverter Gate Solenoid Adjustment

ADJUSTMENT STANDARD: 0.8 mm ± 0.2 mm
1.
Pull the fusing unit all the way out and remove the inverter unit cover
[A] (2 screws).
2.
Slowly push in the plunger [B] of the inverter gate solenoid [C] until the
return pinch roller [D] touches the return drive roller [E].
3.
At this position, measure the rest of the stroke [F]. If the gap is not
within specifications, adjust it by moving the inverter gate solenoid (2
screws).
NOTE:
Whenever adjusting the inverter gate solenoid, confirm and adjust the in-
verter gate position. (Refer to "Inverter Gate Adjustment.")
(Plunger at energized position)