SERVICE TABLES
1. Test Point Table
Number
TP101
TP102
TP103
TP104
TP105
TP106
TP107
TP108
TP109
2. Variable Resister Table
Number
VR101
VR102
VR103
VR104
VR105
VR106
VR107
VR108
3. LED Table
Number
LED101
LED102
LED103
LED104
LED105
LED106
Specification
Belt Motor R.P.M. (Adjust using VR101)
Feed-in Motor R.P.M. (Adjust using VR102)
Inverter Motor R.P.M. (Adjust using VR103)
+5V
GND
+24V
+12V
Not Used
Registration Sensor Signal (Adjust using VR108)
Function
Adjust the separation motor speed.
Adjust the transport motor speed.
Adjust the inverter motor speed.
Not installed on board.
Adjust the 2nd side original registration.
Adjust the 1st side original registration.
Not used.
Adjust the registration sensor signal level.
Function
Exit Sensor ON
Inverter Entrance Sensor ON
Inverter Registration Sensor ON
Not Used
Registration Sensor ON
Feed-in Sensor ON
5-1
12 July '86