12 July '86
1) Image can be easily rubbed
o f f .
Sorter jams may
occur.
If Service Call Condition 6 lights, refer to the Service Call
Section.
Is the fusing temperature correct?
Ready: 178°C
Fusing Lamp ON: 182°C
OFF: 185°C
Y
N
I
Readjust the fusing temperature.
Clean the thermistor surface before adjusting.
Check and adjust the nip band width (8.5
Note:
Use A3 or 11" x 17" paper for this measurement.
Does the copy have a crease mark where the white band appears?
Y
N
° Clean the transfer unit (wire, end blocks, and casing).
Check and replace any defective parts that cause the
°
transfer corona to leak.
Check the paper transport mechanism from paper feed through
t r a n s f e r ; correct any faults.
0.8 mm at the ends).
±