35 Exposure Lamp Voltage
<Function> Varies the
<Remark>
36 Automatic Density Sensor Output
<Function>
<Operation> The exposure lamp lights for 2 seconds and then turns
<Remark>
40 Drum Surface Temperature
<Function> Displays the surface temperature of the selenium drum.
41 Jam Counter 1 (Total Misfeeds)
<Function>
<Remark>
42 Jam Counter 2
<Function>
<Remark>
light intensity of the exposure lamp.
The input
voltage of the lamp can be adjusted in 16
steps. One step corresponds to about 0.65 volts; therefore,
the total change of the input voltage is 10 volts.
Note: Do not adjust the potentiometers of the lamp regulator.
Varies the output voltage of the automatic density sen-
sor.
off for 0.5 seconds. This sequence repeats five times.
The output voltage can be adjusted by turning the poten-
tiometer (VR201) on the main control board.
The voltage is displayed during adjustment.
Displays the total number of paper misfeeds that have occurred
in the copier.
The machine counts the number of paper misfeeds up to
999, then resets the counter at 0.
Displays the total number of paper misfeeds that have occurred
in the following sections of the copier:
1. Paper Feed Section
2. Registration Roller Area
3. Transfer and Separation Corona Area
4. Fusing and Inverter Unit Area
The machine counts the number of paper misfeeds up to
999, then resets the counter at 0.
3-97