12 July '86
|
Is the voltage between CN302-B14 (1,100W) or CN302-
A15 (550W) and TP215 0 volts?
Y
N
I
Replace the main board.
Replace the dc drive board.
Replace the fusing thermistor.
The CPU receives the thermofuse failure signal for more than 2
°
seconds.
Is the thermofuse open circuit?
Y
N
Turn the main switch on.
Is the voltage between 304-B13 and CN303-5 24 volts?
Y
N
Replace RA101.
Replace the thermofuse.