1) Accordion jam
Clean or replace any parts heavily contaminated with toner, such
as, hot roller strippers, oil pad, metering/cleaning blades,
thermistor, hot roller, and pressure roller.
Is silicone oil supplied properly?
N
Y
Check the silicone oil supply mechanism
2 one-way valves
°
rubber sleeve
°
oil pump lever
°
oil cam
°
both fusing lamps properly positioned?
Are
(Refer to the FSM section 3.)
Y
N
Is the fusing temperature in the normal range?
Ready: 182°C
Fusing Lamp ON: 182°C
OFF: 185°C
Y
N
Perform the hot roller temperature adjustment.
If the leading edge of the copy does not have a proper white
margin, readjust the registration or the erase timing.