30
April, '89

3. Inverter Gate Solenoid Adjustment

ADJUSTMENT STANDARD: 0.2 to 1.0 mm
Remove the fusing unit, and remove the inverter unit cover
1.
screws). (Refer to "Fusing Unit Removal".)
Remove the upper exit roller assembly [B] (2 screws).
2.
3.
Confirm if the stroke [C] of the plunger is 1.5 ± 1.0 mm. If
the position of the invertor gate solenoid [D] by two screws
While energizing the inverter gate solenoid manually, confirm if the gap
4.
[F] is is from 0.2 mm to 1.0 mm.
screws [G].
If not, adjust it by the two Allen
5-56