12 July '86
8. Modifying Main Transformer Voltage (220V to 240V)
Remove the lower right cover (2 screws).
1.
2. Disconnect the input line [A] from the 220 V connector [B].
3. Disconnect the dummy connector [C] from the 240 V connector [D].
4. Connect the input line to the 240 V connector.
5. Connect the dummy connector to the 220 V connector.
6. Reassemble.