Installing the needle protection
1. Carefully fit the needle protection (1) with mounting.
2. Secure the needle protection by tightening both screws (2).
Sequence
After removing the needle protection mounting, perform the following setting:
• Needle protection ( Section 10, pg. 56)

3.6.3 Removing and installing the looper and looper mounting

Fig. 15: Removing and installing the looper and looper mounting.
(1) - Adjusting screw
(2) - Screw
(3) - Adjusting screw
Removing the looper mounting and looper
1. Loosen both adjusting screws (1) and (3) slightly.
2. Loosen the screw (2).
3. Remove the looper mounting (4) with looper (5) from the shaft.
Installing the looper mounting and looper
1. Push the looper mounting (4) with looper (5) onto the shaft.
2. Tighten both adjusting screws (1) and (3) a little.
3. Tighten the screw (2) on the looper mounting completely.
Sequence
After removing the looper and the looper mounting, perform the following
setting:
• Looping stroke and looper gauge ( Section 9.6.1, pg. 50)
• Needle protection ( Section 10, pg. 56)
22
(4) - Looper mounting
(5) - Looper
Service Instructions 610/630 - 00.0 - 10/2014
Work fundamentals

Advertisement

Table of Contents
loading

This manual is also suitable for:

630

Table of Contents