DURKOPP ADLER 610 Service Instructions Manual page 86

Hide thumbs Also See for 610:
Table of Contents

Advertisement

9. Select the menu point Tension Top 300g again and measure the
10. When the thread scale shows the value 300 g:
2. Set calibration point 2
1. Select Tension Top 150g.
2. Change the thread tension with +/-1 or +/-10, until the thread scale
3. Exit menu point.
3. Set calibration point 3
1. Select Tension Top 5g.
2. Change the thread tension with +/-1 or +/-10, until the thread scale
3. Exit menu point.
Calibration steps, looper thread
1. Repeat procedure for the looper thread tension for the calibration steps
84
tension value.
Tighten the thread pin (3), without changing the position of the adjusting
nut (2).
reads 150 g.
reads 5 g.
3-1 using the service menus Tension Bottom 300g, 150g and 5g.
Software settings
Service Instructions 610/630 - 00.0 - 10/2014