19.1.4 VHF: IF-2 Filter Select

IF-2
IF-2-Filter menu VHF
Fig. 91
Pushing IF-2 softkey (RX menu VHF) will call up IF-2-Filter menu VHF:
Return to the RX menu VHF (see previous Page).
Select 15.0 kHz IF-2 filter; default filter for AM and FM mode as well as for
SSB if filter bandwidth ≥ 2.9 kHz; the softkey will be displayed inverse.
Select 3.0 kHz IF-2 filter; default filter for SSB mode if filter bandwidth
< 2.9 kHz; the softkey will be displayed inverse (as shown here).
Select 0.5 kHz IF-2 filter; default filter for CW mode;
the softkey will be displayed inverse.
If the Noise Blanker (NB) is activated, the 15 kHz IF-2 filter will always be
selected.
If MODE is changed the default filters will be activated immediately. Same is
true for power-on condition.