Installation / Initial Operation; Introduction; Cable Connectors; Initial Settings - Hilberling PT-8000A Operating Manual

Hf / vhf transceiver
Hide thumbs Also See for PT-8000A:
Table of Contents

Advertisement

PT-8000A Operating Manual v2.00.33
7
I
NSTALLATION
7.1

Introduction

7.2

Cable Connectors

7.3

Initial Settings

Power On
/ I
O
NITIAL
PERATION
Prior to any operation of the PT-8000A read this Operation Manual carefully
notably before activating the transmitter.
The PT-8000A will be delivered with the following presettings:
The preselectors of both RX are aligned and all data are stored in RX-
CPU memory which is buffered through a NiCd battery.
The transmitter is unlocked according to the band plans of that IARU
region (see Page 36) the PT-8000A is delivered.
The IARU region can be changed by software update.
Prior applying main power to the power supply HN-8000 please verify the
following points (7.2).
Please check at the rear panel of PT-8000A and HN-8000:
Antenna(s) is/are connected properly
Grounding stud is connected to station ground
Grounding wire is connected to both PT-8000A and HN-8000
DC cable is connected to both PT-8000A and HN-8000
For initial operation we recommend not to connect external amplifier,
transverter or devices for remote operation.
Please check at the front panel of HN-8000 (see Page 9):
Both switches (LINE und PA) are pushed down (off)
Please check at the front panel of PT-8000A (see Page 12):
Main switch (POWER) is pushed down (off)
Volume controls MAIN and SUB are set fully counter clockwise
TX-PWR knob is set fully counter clockwise
MIC-GAIN knob is set fully counter clockwise
PROC knob is set fully counter clockwise
Microphone T9 is connected
Connect power supply HN-8000 to main power
Turn on both LINE and PA on HN-8000
Turn on POWER at PT-8000A
It is up to the operator to switch PA off (switch PA at the HN-8000) during
reception only.
11