Setting the NIBG
Alarm to activate
before the PIC enters
D CO is highly
recommended.
58
SET NIBG (TISSUE LOADING BAR GRAPH) ALARM
Information includes (Fig. 51):
> Graphic NIBG
> NIBG Set Point (segments), flashing.
Pressing and releasing the S button momentarily (< 2
seconds) will decrease the Set Point from All 5 segments
(Deco) to 1 in increments of 1 segment.
Depressing and holding the S button will scroll through the
Set Points at a rate of 4 Set Points per second until it is
released.
Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the S T
DTR (Dive Time Remaining) ALARM screen with the Set
Point flashing.
Pressing and releasing the A button momentarily and
repeatedly (< 2 seconds each time) will step through the
other S T A screens.
Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert back to the S T A
screen.
Depressing and holding the M button for 2 seconds or if no
button is pressed for a period of 2 minutes operation will
revert to the NORM or GAUG SURF MAIN screen.
FR
Mode has a separate NIBG Alarm.