DELAYED VIOLATION #
The PIC cannot calculate Decompression times for Stop Depths
much greater than 60 FT (18 M) and offers no indication of how
much time spent underwater would result in the need for a
greater Stop Depth.
If the Decompression obligation requires a Ceiling Stop Depth
between 60 FT (18 M) and 70 FT (21 M), the NIBG will flash
and the graphic message D CO > STOP > 60F (18M) will scroll
at the top of the display.
When this occurs, you must make a controlled Ascent to just
deeper than, and stay as close as possible to, 60 FT (18 M)
without causing the NIBG to flash. When the Required Stop
Depth indicates 50 FT/ 15 M, etc., you can ascend to those
Stop Depths and continue decompressing.
DELAYED VIOLATION #3
If you descend deeper than the Maximum Operating Depth of
330 FT (100 M), the UP Arrow will flash, and the Current Depth
and Max Depth displays will only indicate 3 dashes ( - - - )
signifying that you are Out of Range.
The graphic message TOO > D P will scroll at the top of the
display until Ascent is made above 330 FT (100 M).
(Fig. 100)
(Fig. 101)