 Press/release the A button to view the NORM MAIN and
ALT Displays
 Press/hold the A button (2 sec) to view Temperature/Time
 Press/release the L button to activate the Backlight
 Press/release the S button to acknowledge/silence Alarms

DECOMPRESSION DIVE MODE

The PIC is designed to help you by providing a representation
of how close you are to entering Decompression.
Decompression Dive Mode activates when theoretical No
Decompression time and depth limits are exceeded.
Upon ntry into Decompression Mode, the Audible Alarm will
sound, the red L D Warning Light will flash, and the graphic
message D CO > STOP will scroll each 3/4 second On and 1/
4 second Off, until acknowledged or for 10 seconds (unless set
OFF).
Once silenced, the graphics D CO > STOP > xxF or xxM will
scroll each 2 seconds On 2 seconds blank.
 Press/release the S button to acknowledge/silence the
Audible Alarm.
 The UP Arrow will flash if you are greater than 10 FT (3 M)
deeper than the Required Stop Depth (Fig. 92).