Vrs/Disa Error Message Assignment - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000/SL1100
Level
IN
Description
Use Program 25-05 : VRS/DISA Error Message Assignment to assign the VRS message number to
Program
be used as the Automated Attendant error message. For each VRS/DISA trunk that the VRS answers,
enter the VRS message (1 ~ 100) the outside caller hears if they dial incorrectly. If you enter 0 (i.e., no
25
error message), the call reroutes according to Programs 25-03 and 25-04.
For each trunk, make a separate entry for each Night Service mode.
Input Data
Item No.
01
Conditions
None
Feature Cross Reference
• Direct Inward System Access (DISA)
2-282
Program 25 : VRS/DISA Setup

25-05 : VRS/DISA Error Message Assignment

Trunk Port Number
Day/Night Mode
1 ~ 8
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
VRS Message Number
0 ~ 100
(0 = No setting)
Program 25 : VRS/DISA Setup
ISSUE 1.0
Default
0