SL1000/SL1100
Item
No.
07
DP to DTMF Conversion Op-
tions
Determine how a user can con-
vert a Dial Pulse (DP) call to a
DTMF call. For each trunk, set
the type of DP to DTMF conver-
sion required. There are three
conversion options: Automatic
(0), Automatic and Manual (1),
or Manual (2).
Automatic:
DP to DTMF conversion occurs
Program
automatically if the extension
user waits more than 10 sec-
onds before dialing the next
14
digit.
Automatic and Manual:
DP to DTMF conversion occurs
automatically if the extension
user waits more than 10 sec-
onds before dialing the next
digit. In addition, the user can
dial # to switch a DP trunk to
DTMF dialing.
Manual:
Users can dial # to switch a DP
trunk to DTMF dialing.
08
Answering Condition
09
Busy Tone Detection
10
Caller ID
Enable or disable a trunk ability
to receive Caller ID information.
11
Next Trunk in Rotary if No
Dial Tone
Use this option to enable/
disable the system ability to
skip over a trunk if dial tone is
not detected. This option per-
tains to calls placed using
Speed Dial, ARS, Last Number
Redial or Save Number dialed.
It does not pertain to line key or
Direct Trunk Access calls.
12
Detect Network Disconnect
Signal
13
Trunk-to-Trunk Limitation
16
Caller ID Type
18
Busy Tone Detection on Talk-
ing
19
Busy Tone Detection Fre-
quency
20
Busy Tone Detection Interval
Conditions
None
2-102
Item
Input Data
0 = Automatic
1 = Automatic and Manual
2 = Manual
0 = Polarity Reversing
(Polarity)
1 = Polarity Reversing or
Timer (Int Digit)
0 = Disable (No)
1 = Enable (Yes)
0 = No
1 = Yes
0 = Disable (No)
1 = Enable (Yes)
0 = Disable (No)
1 = Enable (Yes)
0 = Disable (No)
1 = Enable (Yes)
0 = FSK
1 = DTMF
0 = Disable
1 = Enable
1 ~ 255
0 ~ 64800 (x 100 ms)
Related Pro-
Default
gram
2
21-01-03
1
21-01-03
0
0
0
0
0
0
0
1
14-02-18
0
14-02-18
Program 14 : Trunk, Basic Setup