ISSUE 1.0
Level
IN
Description
Use Program 34-01 : E&M Tie Line Basic Setup to define the basic settings for each E&M Tie line.
Input Data
Trunk Port Number
Item
Item
No.
01
DID/E&M Start
Signaling
02
Receive Dial Type
for E&M Tie Line
03
E&M Dial-In Mode
04
E&M Line Dial Tone 0 = Disable (No)
05
System Toll
Restriction
Conditions
None
Feature Cross Reference
None
Programming Manual

Program 34 : Tie Line Setup

34-01 : E&M Tie Line Basic Setup
Input Data
Default
nd
0 = 2
Dial Tone
1 = Wink
2 = Immediate
3 = Delay
0 = DP
1 = DTMF
0 = Specify Extension
Number (Intercom)
1 = Use Conversion Table
(NTT)
1 = Enable (Yes)
0 = System
1 = Each Extension
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Description
0
Set the start signaling mode
for DID and Tie trunks. DID
and Tie trunks can use either
immediate start or wink start
signaling.
1
0
Determine if the incoming Tie
Line call should be directed as
an intercom call or if it should
follow the DID Translation
Table in Program 22-11.
1
Enter 1 if the Tie Line should
send dial tone to the calling
system after the call is set up.
Enter 0 if the Tie Line should
not send dial tone.
0
Determine if an incoming Tie
Line call should be subject to
Toll Restriction. If it is set to 0
then it will use the Program
21-05-13, if it is set to 1 then it
will used Programs 21-05-01
~ 21-05-13.
SL1000/SL1100
Program
34
Related Pro-
gram
22-02
10-09
22-11
21-05
2-331