SL1000/SL1100
Level
IN
Description
When Program 44-02-02 is set to type 3, use Program 44-03 : Dial Analysis Extension Table to set
Program
the dial extension analysis table. These tables are used when the analyzed digits must be more than
eight digits. If the received digits do not match the digits set in tables 1 ~ 250, table number 252 is
44
used to refer to the next Extension Table Area (1 ~ 4) to be searched. If the received digits are not
identified in tables 1 ~ 250, the F-Route selection table number defined in table 251 is used.
Input Data
Dial Analysis Table Number : 1 ~ 250
Item No.
01
02
Dial Analysis Table Number : 251
Item No.
03
Dial Analysis Table Number : 252
Item No.
04
Conditions
None
Feature Cross Reference
• Automatic Route Selection (ARS/F-Route)
2-366
Program 44 : ARS/F-Route Setup
Extension Table Area Number
Dial Analysis Table Number
Item
Dial
ARS/F-Route Select Table
Number
Item
ARS/F-Route Select Table
Number
Item
Next Table Area Number
44-03 : Dial Analysis Extension Table
Input Data
Up to 36 digits
Digits = 1 ~ 9, 0,
, #, @
*
(Press Line Key 1 for wild character @)
0 ~ 100 (ARS/F-Route Table Number)
With Program 44-01 set to 0, Program 44-05 is checked.
With Program 44-01 set to 1, Program 44-04 is checked.
Input Data
0 ~ 100 (ARS/F-Route Table Number)
With Program 44-01 set to 0, Program 44-05 is checked.
With Program 44-01 set to 1, Program 44-04 is checked.
0 ~ 4
ISSUE 1.0
1 ~ 4
1 ~ 252
Default
No setting
Default
Input Data
Default
Program 44 : ARS/F-Route Setup
0
0
0