Program 22 : Incoming Call Setup; System Options For Incoming Calls - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
Level
IN
Description
Use Program 22-01 : System Options for Incoming Calls to define the system options for incoming
calls.
Input Data
Item No.
Item
01
Incoming Call Priority
Use this option to determine if Inter-
com calls or trunk calls have answer
priority when both are ringing simulta-
neously.
02
Incoming Call Ring No Answer
Alarm
If enabled, an incoming call that rings
longer than the Ring No Answer
Alarm interval (22-01-03), changes to
a unique ring cadence to indicate that
the call has been ringing too long. If
disabled, this does not occur.
03
Ring No Answer Alarm Time
If a trunk rings a multiline telephone
longer than this interval, the system
changes the ring cadence. This indi-
cates to the user that the call has
been ringing too long.
04
DIL No Answer Recall Time
A DIL that rings its programmed des-
tination longer than this interval di-
verts to the DIL No Answer Ring
Group (set in Program 22-08).
06
DID Ring-No-Answer Time
In systems with DID Ring-No-Answer
Intercept, this sets the Ring-No-
Answer time. This time is how long a
DID call rings the destination exten-
sion before rerouting to the intercept
ring group.
07
DID Incoming Ring Group No An-
swer Time
08
DID Pilot Call No Answer Time
09
DID to Trunk to Trunk no answer
timer
10
VRS Waiting Message Operation
Set up the operation mode for Auto
Attendant and Queuing Message.
11
VRS Waiting Message Interval
Time
Setup the sending duration time of
the Auto - Attendant & Queuing.
The message is repeatedly sent out
during the specified time.
Programming Manual

Program 22 : Incoming Call Setup

22-01 : System Options for Incoming Calls

Input Data
0 = Intercom Call Priority
1 = Trunk Call Priority
0 = Disable (Off)
1 = Enable (On)
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 = Enable Always
1 = Change by Manual Op-
eration
0 ~ 64800 seconds
SL1000/SL1100
Default
Related Program
1
15-02-22
0
22-01-03
22-01-04
60 seconds
22-01-02
0 second
20 seconds
22-12
20 seconds
60 seconds
20 seconds
0
22-14
22-15
22-08
22-04
22-01-04
20-15-11
15-07
20 seconds
22-14-06
22-15-06
41-11-06
Program
22
2-243