I/O Drawer 1 Locations - IBM S85 pSeries 680 Service Manual

Table of Contents

Advertisement

I/O Drawer 1 Locations

FRU Name
I/O drawer 1 (of
0 to 3)
I/O Planar
RIO Controller 1
PCI Controller 5
PCI slot 1
PCI slot 2
PCI slot 3
PCI slot 4
PCI Controller 4
PCI slot 5
PCI slot 6
PCI slot 7
PCI slot 8
PCI Controller 7
PCI Slot 9
Slot
Location Code AIX Location
Name
U0.2
U0.2-P1
U0.2-P1
U0.2-P1
U0.2-P1-I1
U0.2-P1-I2
U0.2-P1-I3
U0.2-P1-I4
U0.2-P1
U0.2-P1-I5
U0.2-P1-I6
U0.2-P1-I7
U0.2-P1-I8
U0.2-P1
U0.2-P1-I9
Physical
Code
Connection
00-00
00-f8D0-0000
60-58 or
I/O Planar J13,
60-58 to
64 bit slot
60-5F or
6B-XX
60-60 or
I/O Planar J4,
60-60 to
32 bit slot
60-67 or
6C-XX
60-68 or
I/O Planar J5,
60-68 to
32 bit slot
60-6F or
6D-XX
60-70 or
I/O Planar J6,
60-70 to 60-7f
32 bit slot
or 6E-XX
00-f8C0-0000
50-58 or
I/O Planar J14,
50-58 to
64 bit slot
50-5F or
5B-XX
50-60 or
I/O Planar J7,
50-60 to
32 bit slot
50-67 or
5C-XX
50-68 or
I/O Planar J8,
50-68 to 50-6f
32 bit slot
or 5D-XX
50-70 or
I/O Planar J9,
50-70 to
32 bit slot
50-77 or
5E-XX
00-f8f0-0000
80-58 or
I/O Planar J15,
80-58 to
64 Bit slot
80-5F or
8B-XX
Chapter 1. Reference Information
Logical
Connection
PCI Controller
5
PCI Controller
5
PCI Controller
5
PCI Controller
5
PCI Controller
4
PCI Controller
4
PCI Controller
4
PCI Controller
4
PCI Controller
7
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterprise server s80Pseries 680 s85

Table of Contents