IBM S85 pSeries 680 Service Manual page 348

Table of Contents

Advertisement

B4xx
Reference Code
Description/Action
Perform all actions before exchanging Failing Items
4592
PCI error detected
An adapter card at the specified location is faulty.
Probability is high.
326
Service Guide
Failing Item
Drawer 1, Slot 2
Location: U0.2-P1-I2
1. Remove any adapters from slots
1, 2, 3, and 4, and retry. If failure
no longer occurs:
a. If only one adapter was
inserted in slots 1, 2, 3, and 4:
1) Replace the adapter and
retry.
2) Replace the I/O planar
and retry.
b. If two or more adapters were
inserted in slots 1, 2, 3, and 4:
1) Retry each adapter
individually in its original
slot. If every adapter
causes a failure then
replace the I/O planar and
retry.
2) If only one adapter causes
a failure then replace the
failing adapter and retry.
3) If replacing the adapter
does not fix the problem,
replace the I/O planar.
2. Go to "MAP 1540: Minimum
Configuration" on page 117.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enterprise server s80Pseries 680 s85

Table of Contents