Terminal Emulators; Recovery Procedures - IBM S85 pSeries 680 Service Manual

Table of Contents

Advertisement

Switch
9
10
11
12
13
14
15
16
* Only switches 11 and 12 are changed from the factory default settings.

Terminal Emulators

The service processor is compatible with simple ASCII terminals, and therefore
compatible with most emulators. It is for the cases when a remote session is handed off
from Service Processor to the operating system that agreeing terminal emulators
becomes important.
The server's operating system has some built-in terminal emulators. Your server may
also have a commercially available terminal emulation. It is important that the local and
host computers select the same or compatible terminal emulators so that the key
assignments and responses match. This ensures successful communications and
control.
For optimum formatting, choose line wrap in your terminal emulator setup.

Recovery Procedures

Line noises, power surges, and so on, can sometimes cause your modem to enter an
undefined state. When it is being used for dial in, dial out or Ring Indicate Power-On,
your modem is initialized each time one of these actions is expected. If one of these
environmental conditions occur after your modem has been initialized, it may be
necessary to recover your modem to a known state.
If your modem communicates properly with remote users, it is probably in control. It is
recommended that you occasionally change some of the functional settings and then
change them back, just for the to ensure that the modem is communicating, and to
ensure it has been initialized recently.
Another strategy, particularly if your system is difficult to access physically, is to protect
it with an Uninterruptible Power Source (UPS) and a phone-line surge protector.
In case recovery becomes necessary, your system should be shut down as using
appropriate shutdown procedures. Disconnect and reconnect modem power, and power
on the system to allow complete reinitialization of your system.
622
Service Guide
Position
Function
Down
Remote Digital Loopback Test Enabled
Up
Dial-Up Line Enabled
*Up
AT Responses Enabled (Extended Responses Disabled)
*Down
Asynchronous Operation
UP
28.8KB Line Speed
Up
Up
CD and DSR Normal Functions
Up
2-Wire Leased Line Enabled