1xxx
Reference
Description/Action
Code
(Perform all actions before exchanging Failing
Items)
9024
SPCN firmware code not valid.
The firmware code in one of the secondary nodes
is not valid. The code will be reloaded.
No action required. This reference code is logged
for error analysis only.
9025
SPCN firmware code is not valid.
The firmware code in one of the frames is not
valid. The code will be reloaded.
No action required. This reference code is logged
for error analysis only.
9028
SPCN firmware code is not valid.
The firmware code in the primary node is not
valid. The code will be reloaded.
No action required. This reference code is logged
for error analysis only.
9029
SPCN VPD damaged
The VPD record in the EEPROM has bad data.
Exchange the failing items for the node reporting
the failure.
902D
Addressed frame is not in SPCN configuration
table.
The addressed frame is not in the SPCN
configuration table.
No action required. This reference code is logged
for information only.
9031
Frame-to-frame communications failure
The SPCN detected a BCC error on a
transmission from another frame. The
transmission is attempted again.
No action required. This reference code is logged
for error analysis only.
206
Service Guide
Failing Item
SPCN card assembly, R21
Location: U1.1-P2-X1