IBM S85 pSeries 680 Service Manual page 337

Table of Contents

Advertisement

Reference Code
Description/Action
Perform all actions before exchanging Failing Items
4585
PCI error detected
An adapter card at the specified location is faulty.
Probability is high.
Failing Item
Drawer 0, Slot 5
Location: U0.1-P1-I5
1. Remove any adapters from slots
5, 6, 7, and 8, and retry. If failure
no longer occurs:
a. If only one adapter was
inserted in slots 5, 6, 7, and 8:
1) Replace the adapter and
retry.
2) Replace the I/O planar
and retry.
b. If two or more adapters were
inserted in slots 5, 6, 7, and 8:
1) Retry each adapter
individually in its original
slot. If every adapter
causes a failure then
replace the I/O planar and
retry.
2) If only one adapter causes
a failure then replace the
failing adapter and retry.
3) If replacing the adapter
does not fix the problem,
replace the I/O planar.
2. Go to "MAP 1540: Minimum
Configuration" on page 117.