IBM S85 pSeries 680 Service Manual page 329

Table of Contents

Advertisement

Reference Code
Description/Action
Perform all actions before exchanging Failing Items
448F
System backplane is faulty. Probability is high.
Perform the following steps before replacing the system
backplane:
1. Check locations M06, M16, and M18 for the
Processor Terminator/filler card, CCIN=246C.
2. Are there any processor Terminator/filler cards in
the system?
NO
YES
3. Turn the system power off if it is not already turned
off.
4. Remove all the Processor Terminator/filler cards.
Use the locations to determine the positions of the
other processor Terminator/filler cards.
5. Select SLOW IPL speed. See operator panel
commands.
6. Power on the system.
7. Does the system boot successfully?
NO
YES
8. Power off the system.
9. Reinstall one of the processor terminator/filler cards
that you removed.
10. Power on the system.
11. Does the system boot successfully?
NO
YES
12. Have you reinstalled all the processor
terminator/filler cards that you removed?
NO
YES
4490
RIO Port 0 or the RIO cable connected to it is faulty.
Probability is high.
Replace the failing item.
Continue with the following step.
Replace the failing item.
Continue with the following step.
The failing FRU is the processor
terminator/filler card you just reinstalled.
Exchange the processor terminator/filler
card. This ends the procedure.
Continue with the following step.
Return to step 8.
The processor terminator/filler cards are
not failing, replace the failing item.
Failing Item
System Backplane, M00
Location: U1.1-P1
1. Check the RIO cable connectors
for damage. Ensure that the cable
connections to the RIO ports are
tight.
2. RIO Cable on RIO port 0.
Location: U1.1-P1-X1/Q1
3. I/O hub card
Location: U1.1-P1-X1
Chapter 5. Error Code to FRU Index
B4xx