This ends the procedure.
24. Have you swapped all the regulator card assemblies?
No
Go to step 25.
This ends the procedure. Go to "Map 0410: Repair Checkout" in the
Yes
Diagnostic Information for Multiple Bus Systems.
25. Perform the following:
a. Power off the system.
b. Remove the new regulator assembly and install the original regulator assembly.
c. Go to step 23 on page 108 to test another regulator assembly.
Reference Code
1201, 1401
1202, 1402
1203, 1204, 1403, 1404
1205, 1206, 1405, 1406
The Possible Failing Regulators are:
R01, R02, R06-R10 Programmable Regulator Assembly
R01, R02, R06-R10 Programmable Regulator Assembly
R04, R05, R06 Memory Regulator Assembly
R01, R02, R06-R10 Programmable Regulator Assembly
Chapter 3. Maintenance Analysis Procedures
109