Reference Code
Description/Action
Perform all actions before exchanging Failing Items
2453
I/O adapter failed. Use the service processor menus
described in "Chapter 7. Service Processor Menus" on
page 447 to view the "Progress Indicators from Last
Boot" panel. If an E5xy checkpoint is recorded as the
first or second entry, the drawer and slot at the time of
failure can be determined from the E5xy checkpoint
information found on page 154. Use this information
when proceeding to "MAP 1540: Minimum Configuration"
on page 117.
2454
I/O adapter failed. Use the service processor menus
described in "Chapter 7. Service Processor Menus" on
page 447 to view the "Progress Indicators from Last
Boot" panel. If an E5xy checkpoint is recorded as the
first or second entry, the drawer and slot at the time of
failure can be determined from the E5xy checkpoint
information found on page 154. Use this information
when proceeding to "MAP 1540: Minimum Configuration"
on page 117.
2455
I/O adapter failed. Use the service processor menus
described in "Chapter 7. Service Processor Menus" on
page 447 to view the "Progress Indicators from Last
Boot" panel. If an E5xy checkpoint is recorded as the
first or second entry, the drawer and slot at the time of
failure can be determined from the E5xy checkpoint
information found on page 154. Use this information
when proceeding to "MAP 1540: Minimum Configuration"
on page 117.
2456
I/O adapter failed. Use the service processor menus
described in "Chapter 7. Service Processor Menus" on
page 447 to view the "Progress Indicators from Last
Boot" panel. If an E5xy checkpoint is recorded as the
first or second entry, the drawer and slot at the time of
failure can be determined from the E5xy checkpoint
information found on page 154. Use this information
when proceeding to "MAP 1540: Minimum Configuration"
on page 117.
2457
I/O adapter failed. Use the service processor menus
described in "Chapter 7. Service Processor Menus" on
page 447 to view the "Progress Indicators from Last
Boot" panel. If an E5xy checkpoint is recorded as the
first or second entry, the drawer and slot at the time of
failure can be determined from the E5xy checkpoint
information found on page 154. Use this information
when proceeding to "MAP 1540: Minimum Configuration"
on page 117.
Failing Item
Go to "MAP 1540: Minimum
Configuration" on page 117.
Go to "MAP 1540: Minimum
Configuration" on page 117.
Go to "MAP 1540: Minimum
Configuration" on page 117.
Go to "MAP 1540: Minimum
Configuration" on page 117.
Go to "MAP 1540: Minimum
Configuration" on page 117.
Chapter 5. Error Code to FRU Index