Operator Panel Function Code Descriptions; Values For Ipl Types And Speeds - IBM S85 pSeries 680 Service Manual

Table of Contents

Advertisement

Table 9. Operator Panel Function Codes (continued)
Function Code
68 xxxx xxxx
69 xxxx xxxx
70 xxxx xxxx
You cannot find the code in this
chart.

Operator Panel Function Code Descriptions

The following describes operator panel functions in more detail.

Values for IPL Types and Speeds

See Table 10 and Table 11 for tables of valid IPL types and speeds used in operator
panel functions 01 and 02.
Table 10. IPL Types
IPL Type
A
B
C
D
Table 11. IPL Speeds
IPL Speed
F:
S:
V = (F or S):
598
Service Guide
Function Selected
Reserved
Reserved
Reserved
If you cannot find the function code in this chart, the customer
support for added features or devices may not have been
available when this information was produced. Look for any
supplement unit function code information for the function code
you have displayed on the operator panel. If you do not find
any additional function code information, go to "Function 04 -
Lamp Test" on page 600 and verify that the lamps are working
correctly.
Description
IPL using copy A of the system firmware.
IPL using copy B of the system firmware.
Attention: Not supported; may cause data loss if used.
Attention: Not supported; may cause data loss if used.
Description
Fast Override
Slow Override
Use system selected
speed
Details
Fast diagnostics run. The following are
skipped:
v Mainstorage tests
v CEC Inter-chip interface tests (wire test)
v Extended Logical Built-in Self Tests
v Also, cache data is not provided in
mainstorage dumps.
Full hardware diagnostics run. Use whenever
hardware is changed, for intermittent hardware
failures and on the first install IPL.