E6581341⑩ TOSVERT VF-AS1 / VF-PS1 Expansion IO Card Option 2 Instruction manual ETB004Z Note 1. Read this manual carefully before using the inverter. After reading, the user should keep this manual at hand to use it for maintenance and inspection in the future.
Limits in purpose Safety precaution ▼ Never use this unit with any device other than TOSVERT VF-AS1/PS1 series inverters. Doing so may cause an accident. WARNING ▼ Never disassemble, modify or repair. This can result in electric shock, fire and other injuries. Please call your Toshiba distributor or service window for repairs.
Page 3
▼ Do not install and operate the inverter if it is damaged or any of its components are missing. This will result in electric shock or fire. Please call your Toshiba distributor or service window for repairs. ▼ Do not place any inflammable object near the inverter.
E6581341 NOTICE ▼ Do not pull the cable connected to the terminal blocks. This can result in damage or malfunction. Prohibition Operations WARNING ▼ Do not touch switches when the hands are wet and do not try to clean the inverter with a damp cloth.
E6581341 Introduction Thank you for purchasing a “Expansion IO card option 2” for industrial inverter TOSVERT VF-AS1/PS1 inverter. By the use of this option, the expansion of input/output terminal is possible. This instruction manual describes connecting method and usage of the “Expansion IO card option”.
E6581341 Contents Safety precautions ......................1 Notes on use ........................3 Introduction ........................4 Contents ......................... 5 1. Name and function of each section ................6 1.1. Appearance ......................6 1.2. Name of each section (terminal) ................. 6 2. Installing the IO card option in the VF-AS1/PS1 ............7 2.1.
E6581341 1. Name and function of each section Following figure shows appearance and name of each section of the expansion IO card option. 1.1. Appearance Inverter cover hook for the fixation SINK/SOURCE Select SW SOURCE SINK(PLC) SINK(INT) 1.2. Name of each section (terminal) Programmable relay output 2 TH2+ PTC input terminal (+)
E6581341 2. Installing the IO card option in the VF-AS1/PS1 Install the IO card option to VF-AS1/PS1 as follows: *1 When this option is used together with the communication option, attach this option to the inverter side. 2.1. Connection to the inverter (1) Turn off input power before installing.
Page 9
E6581341 (B) For VFAS1/VFPS1 200V 55kW or more, 400V 90kW or more a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front panel, release the panel mounting tab by pushing the screwdriver down, and remove the front panel cover.
E6581341 2.2. Wiring When conducting wiring, follow the instructions below. • Use shield wire for control signal line and ground the unit with shield wire (Use twisted pair shield cable for wiring of the analog monitor output.) • Never bind the signal line and main circuit connection wire together. •...
Page 11
E6581341 Terminal Function Electrical specification Internal circuit symbol The resistance between TH2+ and TH2- 3kΩ TH2+ Voltage Tripping value: about under 50 Ω TH2+ Thermal trip input detection 10kΩ TH2- or over 3k Ω circuit TH2- Reset value: about 1.8k Ω N10 -10V power supply DC-10V - 10mA...
E6581341 3. Functional description In this section, functions added by the installation of this expansion IO card option, on top of the standard inverter functions, are described. Note: When power on or reset the inverter, the initialization of the ETB004Z terminal inputs and outputs are delayed about 300ms from the inverter own terminals.
E6581341 Monitor Refer to the description on status monitor mode of inverter’s instruction manual. The input terminal status can be monitored by the input terminal status parameter ( fe06 ), and the parameter can be monitor by the serial communication. fe06 bit No.
E6581341 3.6. Analog input (AI2) The frequency command can be input from the voltage or current analog input. Parameter Title Function Adjustment range Default setting Analog AI2 (optional circuit board) 0: Voltage f109 voltage/current switching 1: Current f228 AI2 input point 1 setting 0 - 100% f229...
E6581341 3.8. Pulse train input (RP) The frequency command can be input from the pulse train input. Parameter Title Function Adjustment range Default setting 1 - 12 fmod Frequency setting mode selection 1 11: RP pulse input f234 RP/high speed pulse input point 1 setting -100 - 100% f235...
E6581341 4. External diagram Do not forget to reserve the space for the options at time of installation. External diagram of option (unit: mm) Dimension of optional unit The control panel depth increases about 21.6mm when the option is installed. Secure the front space from the inverter control panel fully.
E6581341 5. Specification <Environment Specification> Item Specification Indoor, less than 3,000 m from the sea level. Use Environment No direct sunlight, corrosive or explosive gas, steam, cutting dusts or dusts, grinding solution, and grinding oil. - 10 to + 60 ℃ Ambient Temperature - 25 to + 65 ℃...