REMOTE / THERMOSTATIC CONTROLLED OPERATION

REMOTE CONTROLLER - SYNCHRONISATION.

Before proceeding with synchronisation ensure that the gas and electricity are connected.
Synchronisation must be carried out when a new controller has been purchased. Two controllers
NOTE
CAN NOT be used at the same time!
The heater will not respond the controller until synchronisation has been carried out.
Synchronisation of Controller & The Heater
Step 1).Turn the power off at the power point for a minimum of 30 seconds, synchronisation will not be
possible unless the minimum 30 seconds has been observed.
Step 2).Ensure the remote control is turned OFF, to turn OFF press and release the 'PWR' button once.
Step 3).Turn the power ON at the power point, the blue power operation indicator
button control panel will flash once. The controller can now be synchronised with the heater.
Synchronisation MUST BE performed within 30 seconds of the power being turned ON, if more than
30 seconds has elapsed repeat steps 1 through 3.
NOTE
Step 4).On the controller in quick succession press the following sequence of buttons: 'P' > 'T' > 'T' > 'UP'
The LCD display will show 'L/C' (Learn Code) for 2 seconds then return to the normal 'OFF' state display.
The blue power operation indicator
synchronisation has been accepted.
To restore factory default settings
With the thermostat 'OFF', press the following sequence of buttons 'P' > 'T' > 'T' > 'DOWN'.

REMOTE CONTROLLER - MANUAL OPERATION

Turning 'ON'
Step 1).Press 'ON'/'OFF' button of the Push Button Control Panel
illuminate blue.
Step 2).Press both the 'OK' and 'PWR' buttons on the controller at the same time. Operational control is now
transferred to the controller, the heater operation is then dependant on the controller mode as follows:
In Manual Mode - Unless the set temperature is above that of the room temperature the heater will not
ignite and the power Indicator LED
mode. Raising the set temperature above that of the room temperature will start heater operation and the
Power Indicator LED
Turning 'OFF'
Step 1).To place heater into controller standby press the 'PWR' button once. The heater will go into 'Standby'
mode and the power Indicator LED
Step 2).To turn the heater 'OFF' press the 'ON'/'OFF' Button
extinguished to indicate that the appliance has returned to the OFF condition.
Changing the temperature
The Sapphire has temperature increments of 1° which can be changed using the 'UP' and 'DOWN' buttons.
The temperature control range is 7 - 32°C
Change between Celsius - °C and Fahrenheit - °F
The thermostat temperature display can be set to °C or °F. The default is °C.
With the controller 'OFF', press the following sequence of buttons: 'P' > 'T' > 'T' 'A/M' to toggle between °C or °F.
Change between manual, automatic and flame modes
Press and release the 'A/M' button.
The unit first lights the pilot and then after a short period switches to the 'HIGH' flame setting.
To turn 'OFF' press and release the 'PWR' button once.
Rinnai Australia
on the push button control panel will flash once to indicate that
b
will turn red to indicate that the heater is in Controller Standby
b
, will change from red to blue.
b
will turn red.
b
once the Power Indicator LED
a
twice. The Power Indicator LED
a
11
a
b
on the push
b
b
, will be
b
Sapphire Operation & Installation Manual
, will

Hide quick links: