Operation without the remote
If you lose your remote, or the batteries go flat, you can still operate your fire, albeit in a limited
capacity, using the control panel on the unit.
How the fire starts
The Arriva has a sealed combustion chamber that requires purging before gas can flow and the
unit can start. This means the combustion fan will start before the unit comes on.
Ignition sequence
1. When the On/Off button is pressed on the control panel, the LED will glow red and the
combustion fan will start.
2. The ignition sparker will operate as soon as a spark is sensed and gas will flow to the main
burner.
3. When the main burner has established, the unit will automatically modulate between the burner
settings to achieve and maintain the default set temperature of 22 °C.
If the fire is turned off using the on/off button on the control panel, when it is turned back on it will
lose any timer and clock settings until the remote is used again to re-transmit the information. The
remote stores the clock, time, and temperature settings of the fire.
Do not unplug the power supply
Do not unplug the main power supply to the fire as the convection fan is required to operate for
several minutes after the unit is turned off to assist in cooling the fire down.
Arriva 752 operation guide: 12219-C 03-20 | 9