Owner’s Operation and Installation Manual for the RHFE-750ETRA Direct Vent Fireplace Table of Contents ... 2 Safety Information ..2 Operating Instructions ..6 Care and Maintenance ... 11 Fault Codes ....14 Installation Instructions .. 15 Consumer Support ..38...
Indicates a potentially hazardous situation which, if not avoided, could result in death or WARNING serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in minor or CAUTION moderate injury. It may also be used to alert against unsafe practices. Rinnai Corporation RHFE-750ETRA...
• Spark Detector: The appliance automatically shut down if the burner flame is extinguished. shuts down if there is an abnormal spark at ignition. • Power Failure: The appliance will cut off the gas if it loses electrical power. Rinnai Corporation RHFE-750ETRA...
(features are the same for flat and curved models) Front Panel Models Description Part Number Flat Metal - Black Front R2700 Flat Metal - Stainless Steel Front R2701 Radius (curved) Glass - Silver Front R2702 Radius (curved) Glass - Black Front R2703 Rinnai Corporation RHFE-750ETRA...
O - I switch going to be used for a long period. • Some fluorescent lights may interfere with the transmission of remote control signals. • Avoid leaving the remote control in direct sunlight. Rinnai Corporation RHFE-750ETRA...
Operation Indicator to glow green. follows: • when the lock function is activated • when setting the timers, timer information is transmitted only when the “TIME SET” button is pressed and released Rinnai Corporation RHFE-750ETRA...
AUTO OFF again. Temperature Time To cancel the Lock Whether this mode is on or off, the appliance will function press down and attempt to maintain the temperature setting. hold the LOCK button for 3 seconds. Rinnai Corporation RHFE-750ETRA...
TIMER 1 and/ or TIMER 2 button. The display will briefly show the “on” and “off” times for each timer. If the current time is outside of the Timer 2 programmed times then the appliance will Rinnai Corporation RHFE-750ETRA...
This appliance has two filters which are behind the louvers on either side of the heater. The louvers are hinged to allow access to the filters. Dirty filters reduce the air flow and the appliance’s NORMAL ABNORMAL Rinnai Corporation RHFE-750ETRA...
8. Install the top panel with one screw on each side of the side louvers. Refer to Final Assembly. Care of Exterior Clean exterior as required using non-abrasive and non-solvent cleaner. Ensure exterior is completely dry before operating. Rinnai Corporation RHFE-750ETRA...
Timers do not turn the appliance ON or OFF Timers may be turned off or incorrectly programmed. Timer turns the appliance ON briefly and then the The room temperature may be higher than the temperature appliance turns OFF before the OFF time setting. setting. Rinnai Corporation RHFE-750ETRA...
2. Remove the right hand side panel to allow access to the gas control and main PCB. 3. Unplug the thermal fuse harness (including the control plug for the POV on the gas control) and unscrew thermal fuse. 4. Re-assemble with replacement thermal fuse. Rinnai Corporation RHFE-750ETRA...
2 AAA batteries • 3 screws (2 long screws for the remote control • log set (7 pieces) holder and 1 short screw for the flue clamp) • ball valve (on/off valve for gas line) • condensate tray Rinnai Corporation RHFE-750ETRA...
Side view Flue Terminal Clearances TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE FIXED CLOSED AIR SUPPLY INLET OPERABLE VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTTED Rinnai Corporation RHFE-750ETRA...
Page 17
2 Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier. Rinnai Corporation RHFE-750ETRA...
These dimensions are the minimum required if using the minimum width, height, and depth dimensions above. Enclosure Dimensions in a Corner 63.8 in (1620 mm) 45.1 in (1146 mm) 31.9 in (810 mm) Rinnai Corporation RHFE-750ETRA...
Disassemble the flue manifold by first pulling out the inside connection. To remove the outer terminal pull and release the two internal ties and then pull out the outer terminal. Sleeve Clearance to combustibles for the sleeve and flanges is zero inches. Rinnai Corporation RHFE-750ETRA...
Page 21
From the outside insert the terminal into the sleeve with the marking “TOP” at the top. The left hand side locking tie should be marked “LEFT”. Terminal Locking tie Rinnai Corporation RHFE-750ETRA...
If it becomes necessary to access an enclosed vent system for service or repairs, Rinnai is not responsible • Support horizontal vent runs every four feet and for any costs or difficulties in accessing the vent all vertical vent runs every six feet or in system.
Page 23
Follow the guidelines on the opposite page and follow the Metal-Fab installation instructions for installing the venting. Refer to the Metal-Fab direct vent system components catalogue to determine the parts required for you particular vent application. Rinnai Corporation RHFE-750ETRA...
Page 24
The distance between the wall and the air inlet cover should be 1.0 - 2.36 inches (25 - 60 mm) Vent Length Switch If using extended venting, move Vent Length Switch the dip switch in the control panel to L-F. Rinnai Corporation RHFE-750ETRA...
Attach the cover with 2 screws. 8. Leak test the gas connection using a soapy solution. Do not allow the soapy solution to contact electrical components. Remove any residue. gas connection gas fitting opening Rinnai Corporation RHFE-750ETRA...
Page 26
K to pipe J making sure that the clip in elbow K goes beyond the groove in the pipe. The gas supply flexible hose is designed to coil inside the appliance as it is pushed into the enclosure. Rinnai Corporation RHFE-750ETRA...
8. Place the left hand front log and the right hand front log on the pins. left hand front 9. Install the glass panel with two retainer screws at right hand front the top of the panel. Step 8 Rinnai Corporation RHFE-750ETRA...
Place it flat so that it matches up with the shape of the lower panel. One edge of the tray has a short lip. Position the tray so that this lip is towards the front of the appliance. Condensate tray Front of appliance Lower panel Condensate tray Lower panel Rinnai Corporation RHFE-750ETRA...
3. Set the top panel into place. Open the side louvers and on each side attach the top panel with one screw. (Side louvers are opened by pushing in and releasing.) Rinnai Corporation RHFE-750ETRA...
Once compartment clean. See installation and the fan has stopped operating, isolate the appliance operating instructions. power by unplugging it from the wall or turning off the isolating breaker switch. Rinnai Corporation RHFE-750ETRA...
ALSO COMES AS PART OF 10506 HARNESS COMB FAN THERMISTOR COMBUSTION FAN 10435 TUBE CONDENSATE LOWER 10438 TUBE SILICON BLACK 7X4X80 10465 CLIP HOSE 6mm 10531 CONDENSATE TRAY 380mm ** Always refer to the data plate for correct information. Rinnai Corporation RHFE-750ETRA...
This Warranty only extends through the first installation of the product and terminates if the product is moved or reinstalled at a new location. How long does coverage last? RHFE-750ETRA Warranty (from date of purchase) Heat Exchanger 10 years...
Page 39
What will Rinnai do? Rinnai will repair any part or component that is defective in materials or workmanship as set forth as follows. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai.
Page 40
Manufactured by Rinnai New Zealand LTD 105 Pavilion Drive, Airport Oaks Mangerg, Manukau City New Zealand 15237 (Issue G)