TO TURN YOUR HEATER ON

BEFORE PROCEEDING ENSURE THE GAS AND ELECTRICITY ARE TURNED ON.
When the heater is in the OFF condition (the power supply connected and switched ON but the
NOTE
heater turned OFF) the Power Indicator will be extinguished, this is normal.
The 'Push Button Control Panel' is located at the
top left edge of the heater.
Step 1. Press 'ON'/'OFF' button
electronic ignition sparker will be able to
be heard.
Step 2. The electronic ignition stops when the
pilot flame has been established, the
main burner then ignites off the pilot
and is automatically preset to Stage 7 -
High Flame. The blue LED Power
Indicator,
b
illuminated
indicating
operation.
Step 3. Flame height may be adjusted after 1
minute of operation. To change the
burner and fan settings press
increase flame height and
decrease flame height.
FLAME HEIGHT & FAN SPEED SETTINGS
The relationship between the flame
height and fan speed are preset and
NOTE
can not be independently adjusted.

TO TURN YOUR HEATER OFF

When the heater is in the OFF/STANDBY condition (power supply connected and switched ON) the
blue LED Power Indicator will be extinguished. This is normal.
NOTE
To turn the heater 'OFF' press the 'ON'/'OFF' Button
indicate that the appliance has returned to the in OFF condition.

INTERRUPTION TO ELECTRICITY OR GAS SUPPLY DURING OPERATION

Interruption to the power or gas supply will turn your heater off. Restart will be required This is a safety feature
designed to ensure that un-attended starts do not occur.

RESTART PROCEDURE AFTER INTERRUPTION TO ELECTRICITY SUPPLY

To restart your heater once power has been restored follow the steps for "TO TURN YOUR HEATER ON" above.

RESTART PROCEDURE AFTER INTERRUPTION TO GAS SUPPLY

The instant gas supply is interrupted the heater will attempt re-ignition for a period of 60 seconds.
If the heater has not re-lit after 60 seconds the gas control will go to 'Gas Lock-out'. The convection fan will remain
on for 4 minutes to cool the appliance.
To restart your heater once gas has been restored:
Step 1. Ensure gas supply has been re-established to heater.
Step 2. To re-set the gas control turn 'OFF' the heater by pressing 'ON/OFF' button
Step 3. In rapid succession Press button
period.
Rinnai Australia

CONTROL PANEL OPERATION

once. The
a
will
be
constantly
heater
is
in
to
c
to
d
, 3 times. (Turn 'ON', then 'OFF', then 'ON' again), within a 5 second
a
a
b
c
d
FLAME HEIGHT
1
FAN SPEED
HIGH LOW LOW LOW HIGH HIGH HIGH
once. The blue LED Power Indicator
a
9
2
3
4
5
, will extinguish to
b
once.
a
Sapphire Operation & Installation Manual
6
7

Hide quick links: