4.4.16 Release Holder Assy

1.
Remove the APG Assy. (p.89)
2.
Release the PE Sensor connector cable from the five tabs on the Release Holder
Assy.
3.
Remove the three C.B.S. M3 x 6 screws that secure the Release Holder Assy.
4.
Remove the three lower tabs of the Release Holder Assy from the Main Frame
with a flathead screwdriver, and remove the Release Holder Assy upwards.
Rear side
3
Release Holder Assy
2) C.B.S. M3x6
Front side
Upper Tabs
Figure 4-148. Removing the Release Holder Assy
Disassembly And Assembly
Tabs
PE Sensor connector cable
2
1
(8±1 kgf.cm)
Lower Tabs
Disassembling the Printer Mechanism
Align the three upper tabs on the Release Holder Assy with the
positioning holes on the Main Frame.
Fit the FLAG Release Shaft by the bushings on the Release
Holder Assy.
Bushings
FLAG Release Shaft
Figure 4-149. Reinstalling the Release Holder Assy
Tighten the screws in the order shown in
Revision E
See Figure 4-148.
Figure 4-148