24 - 8
HEATING AND AIR CONDITIONING
DIAGNOSIS AND TESTING (Continued)
move towards the Cold position. When Pin 13 is High
and Pin 15 is Low the door will move towards the
Heat position. When both Pins are high or when both
Pins are low, the actuator will not move. The Driver
feedback signal is a voltage signal that is supplied by
the actuator to the control. The signal will be about
4.0 volts in the Heat position and 1.0 volt in the Cold
position. As the position of the Driver Actuator
changes, so will the feedback signal. The feedback
signal is necessary for the correct positioning of the
temperature door.
MODE ACTUATOR BACKGROUND
The Mode actuator can move the mode door in two
directions. When the voltage at Pin 18 of the control
module is high, about 11.5 volts, and the voltage at
Pin 12 is low, about 1.5 volts the door will move
towards the Panel position. When Pin 12 is High and
Pin 18 is Low the door will move towards the Defrost
position. When both Pin are high or when both Pins
are low, the actuator will not move. The Mode door
feedback signal is a voltage signal that is supplied by
the actuator to the control. The signal will be about
4.5 volts in the Panel position and 0.5 volts in the
Defrost position. As the position of the Mode actuator
changes, so will the feedback signal. The feedback
signal is necessary for the correct positioning of the
mode door.
FAIL CODES/LEVEL DISPLAY
Fail Codes/Level are displayed using the REAR
WIPER and INTERMITTENT LED's flashing in the
sequence indicated below. The REAR WIPER LED
represents the Level and the INTERMITTENT LED
represents the Value. After Calibration/Diagnostics is
completed, the control will begin flashing Level 1
codes. Depressing the WASH button will cycle to
Level 2, depressing WASH again will cycle to Level 3.
Each time the WASH button is depressed will cycle
to the next level. After Level 5 is reached, you will
cycle back to Level 1. If the Control is a Heater Only
you will only cycle from Levels 1 to 3.
WIPE BUTTON LED
LEVEL
1
FAIL CODES
2
MODE POTENTIOMETER TEST
3
BLEND/PASS. POTENTIOMETER TEST
4
EVAPORATOR PROBE (A/C AND ZONE
UNITS ONLY)
5
DRIVER POTENTIOMETER (ZONE UNITS
ONLY)
DISPLAY
LEVEL 1–FAILURE CODE VALUES
(INTERMITTENT WIPE BUTTON LED)
CODE
0
PASSED ALL TESTS
1
MODE ACTUATOR DID NOT REACH
DEFROST POSITION
2
MODE ACTUATOR DID NOT REACH
PANEL POSITION
3
BLEND/PASS. ACTUATOR DID NOT
REACH COLD STOP
4
BLEND PASS. ACTUATOR DID NOT
REACH HEAT STOP
5
EVAPORATOR PROBE OPEN
6
EVAPORATOR PROBE SHORTED
7
DRIVER ACTUATOR DID NOT REACH
COLD STOP
8
ZONE/DRIVER ACTUATOR DID NOT
REACH HEAT STOP
9
CONTROL HEAD INTERNAL FAILURE
TEMPERATURE AND MODE POTENTIOMETER
DIAGNOSTICS
The Temperature and Mode Potentiometer can be
tested after calibration is complete by pressing the
WASH button and cycling to Levels 2, 3 or 5 as dis-
played by the REAR WIPER LED. On Heater Only
units you can only cycle to Levels 2 and 3. In each
individual test the INTERMITTENT LED flash rate
will change as the Temperature or Mode potentiome-
ter is moved from one end to the other, see Potenti-
ometer vs. Position and Flash Rate table.
POTENTIOMETER VS. POSITION
AND FLASH RATE
INTERMITTENT
POTENTIOMETER
LED FASTER
FLASH RATE
MODE
PANEL
BLEND/PASS.
HOT
DRIVER
HOT
EVAPORATOR PROBE TEMPERATURE
DIAGNOSTICS
The evaporator probe can be tested by using the
INTERMITTENT LED to display the actual temper-
ature the sensor is reading. The HVAC control mod-
ule can only display temperatures from 1 to 99
degrees. To read the temperature, perform the follow-
ing:
• Set Blower motor to any speed other than OFF
NS/GS
DEFINITION
INTERMITTENT
LED SLOWER
FLASH RATE
DEFROST
COLD
COLD