Signal line name
RHV
TH2
EEPROM DATA
EEPROM CLOCK
NSC VD
NSC VC
FUSER STS
HEAT1
xHEAT1
HEAT2
xHEAT2
Heater rated power:
MAIN:550 ± 27.5W (120VAC/230VAC)
SUB :330 ± 15.0W (120VAC/230VAC)
Thermostat contact open temperature: 180 ± 5°C
Chapter 7 Wiring Diagrams and Signal Information
Data on humidity inside the device (analog value)
Data on temperature inside the device (analog value)
Control signal of EEPROM
Control signal of EEPROM
Data on temperature of the temperature control sensor (analog
value)
Data on temperature of the temperature control sensor (analog
value)
Data on temperature of the high temperature detection sensor
(analog value)
Control signal for Main Lamp placed in FUSER ASSY (LAMP
lights up at "High:HEAT1 and "Low:xHEAT1")
Control signal for Sub Lamp placed in FUSER ASSY (LAMP
lights up at "High:HEAT1 and "Low:xHEAT1")
7 – 19