Motor, Clutch and Solenoid
name (Diag. Code)
REGI Clutch (DO-50)
1)
Turn on the power and enter the Diagnostic Mode.
2)
Execute the DO-50. Upon pressing the "
operation noise of the clutch is heard.
3)
Press the "CANCEL" key to stop the test.
Combination test is as follows.
NOTE: The Regi Roll rotates when the DO-0 and DO-50 are
executed. The following procedures are for the technical staff.
1)
Turn on the power and enter the Diagnostic Mode.
2)
Push up the Front Latch to open the Front Cover.
3)
Cheat the safety Interlock System.
4)
Execute the DO-0 and DO-50. Confirm the rotation of the Roll
Regi Metal and Roll Regi Rubber on the Retard and Regi Assy.
Roll Regi Metal
2)-2
2)-1
5)
Press the "CANCEL" key to stop the REGI Clutch test (DO-50
test).
6)
Press the "
" key to display the DO-0.
7)
Press the "CANCEL" key to stop the Main Motor (DO-0 test).
8)
Remove the cheater.
9)
Close the Front Cover.