Figure 28: Optional Dx2010 Mounting Locations; Figure 29: Dx2010 To Control Panel Wiring; Table 5: Dx2010 To Control Panel Wire Length; Table 6: Dx2010 To External Power Supply Wire Length - Bosch DS7200V2-EXP Installation Manual

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup
Figure 28:
Optional DX2010 Mounting
Locations
1
2
1- Control panel board location
2- DX2010 optional mounting location
Up to five DX2014 modules can be connected to
the DS7240V2 (up to 2 on a DS7220V2). See
Figure 29 for wiring details.
2.6.3
DX2010 Wiring
Do not use twisted pair or shielded cable when
wiring the DX2010.
See the following tables for Data Bus wire length
requirements.
Table 5: DX2010 to Control Panel Wire
Length
Power
Source
Aux Output
Control
Not Used
Panel
Aux Output
Used
Aux Output
External
Used or Not
Power
Used
Supply
Table 6: DX2010 to External Power Supply
Wire Length
Aux Output
Not Used
Aux Output
Used
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
6
5
08 mm
1.2 mm
(#22
(#18
AWG)
AWG)
305 m
610 m
(1007.7 ft)
(2001 ft)
30 m
76 m
(98.4 ft)
(249.3 ft)
305 m
610 m
(1007.7 ft)
(2001 ft)
08 mm
1.2 mm
(#22 AWG)
(#18 AWG)
305 m
610 m
(1007.7 ft)
(2001 ft)
30 m
76 m (249.3
(98.4 ft)
ft)
Connect the control panel's Data and Aux Power
terminals to the DX2010 as shown in Figure 29.
If the DX2010's Aux Output ("+Out-"
terminals) is used as an auxiliary
power source, the DX2010's "R" and
"B" wires must be "home-run" to
either the control panel or to an
available power supply. Do not use a
daisy-chain wire configuration.
Figure 29:
DX2010 to Control Panel
Wiring
1
+OUT-
TMPR
R
B
1- DX2010 module
2- Green (G) data wire
3- Yellow (Y) data wire
4- Black (-) wire
5- Red (+) wire
6- Control panel board
You can use either one of the Aux Power (-)
terminals and either one of the 12 VDC (+)
terminals when connecting devices to the control
panel.
EN | 24
6
2
3
G
Y
1 COM
4
5
BATT+
BATT-