DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup
2.6.9
DX2010 Addressing
Any time you change the address DIP
switches, cycle the power to the
module OFF and then ON for the
changes to take effect.
Use Table 9 to set the address jumpers for all
DX2010s connected to the control panel.
Shaded rows only apply to the DS7240V2.

Table 9: DX2010 Address Settings

Locatio
Standard
n
Sensor Loop*
1 to 8
Data Bus Addr
101
9 to 16
Data Bus Addr
102
17 to 24
Data Bus Addr
103
25 to 32
Data Bus Addr
104
33 to 40
Data Bus Addr
105
* For Standard Sensor Loop, set the location's
"Device" parameter to "2." Set the DX2010
address as shown in Table 10. See Location ##,
Device on page 82 for programming details.
** For Doubled Sensor Loop, set the location's
"Device" parameter to "3." Set the DX2010
address as shown in Table 10.
For tamper-wired zones, use Data Bus Addresses
101 to105. Set the device type settings to "2"
(see Location ##, Device on page 82).
Set the address DIP switches as shown in Table
10.
Shaded rows apply only to the DS7240V2.
Table 10:
DX2010 DIP Switch Settings
DX2010 DIP Switch Settings
DIP
S1
S2
Switche
s
Module
32
16
Address
101
OFF
OFF
102
OFF
OFF
103
OFF
OFF
104
OFF
OFF
105
OFF
OFF
106
OFF
OFF
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Doubled
Sensor Loop**
Data Bus Addr
106
Data Bus Addr
106
Data Bus Addr
107
Data Bus Addr
107
S3
S4
S5
S6
8
4
2
1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
107
OFF
OFF
See Figure 37 for proper DX2010 DIP switch
configuration.
Figure 37:
DX2010 DIP Switch
Configuration
1
ON
1
2
1- OFF position
2- ON position
Sample address setting shown is for Address
102
2.6.10 DX2010 Status LED
See the following for Status LED operation:
One flash per second indicates normal
operation.
LED steady ON can indicate any of the
following:
Power, no communication.
-
"G" wire is not connected or there is a
-
communication problem between the
control panel and the DX2010.
No locations (zones) are assigned to the
-
DX2010 with this address. See Location
##, Zone Function on page 83 for details.
DX2010 address is not set correctly.
-
LED OFF indicates that there is no power to
the module.
Figure 38:
DX2010 Status LED Location
1- DX2010 DIP Switches
2- DX2010 Status LED
EN | 28
OFF
ON
ON
2
3
4
5
6
ON
1
1
2
3
4
5
6
2
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents