DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
Table 34:
Output Function Types (continued)
Digit
Digit
1
2
2
0
[P] Key (Rising Sun Key on RF
Fob)
2
1
'Panic' on RF Fob
2
2
'Panic' on RF Fob, Bell Time,
PIN resets
2
3
[A] Key
2
4
[B] Key
2
5
[C] Key
2
6
3 Unsuccessful Dialing
Attempts
2
7
Communication Fail Event
2
8
Panel Off Hook
2
9
Ring Detect
2
10
Voice Request
2
11
Follow Keypad Sounder
2
12
Chime
2
13
Ready to Arm (No zones
faulted)
2
14
Exit Error/Bad Set
2
15
AC 60 Hz
3
0
Ground Start
3
1
Follow Zone Function 1
3
15
Follow Zone Function 15
4
0
Change Outputs
4
1
Alarm Zone Function 1
4
15
Alarm Zone Function 15
5
0
Change Outputs
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Function Type
Activates when Rising Sun Key on RF Keyfob is pressed. [System Reset]
resets. Pressing P (sun) key again also resets output when Output Mode
is set to Toggle. This output type is event-driven. See Mode (Steady,
Pulse, One Shot), Output ## on page 93 for more information.
Activates when Arm Key (locked icon) and Disarm Key (unlocked icon)
on RF Keyfob are pressed at the same time, or when the [Q] button is
pressed and it is set to Duress. See the DS7200V2 Expert Programming
Guide (P/N: 4998153891) for [Q] button information. [#][4][7] resets.
Activates when Arm Key (locked icon) and Disarm Key (unlocked icon)
on RF Keyfob are pressed at the same time, or when the [Q] button is
pressed and it is set to Duress. Steady and Pulse modes follow bell time.
PIN resets.
Activates when appropriate keys are pressed. [System Reset] resets if no
alarm response is assigned. These output types are event-driven. See
Mode (Steady, Pulse, One Shot), Output ## on page 93 for more
information.
Activates after 3 unsuccessful dialing attempts. Resets with first
successful call or [System Reset].
Activates after Communication Fail Event. Resets with any successful
communication or [System Reset].
Activates when the control panel takes the phone line off hook for a
dialing attempt. Resets when the control panel finishes with the phone
line and goes on hook.
Activates when the control panel detects a ring on the phone line. Resets
when ringing stops.
For use with an optional Voice Verification Module. The output activates
for 2 sec when the control panel receives an acknowledgement of an
alarm report from a zone with the Voice Verification option enabled.
Mode and Time parameters do not apply.
Available for on-board outputs only. Output follows keypad sounder
Mode and Time parameters do not apply.
Activates per Chime configuration. Follows keypad sounder per Chime
Tone configuration.
Output is activated (on) when: (1) control panel is disarmed & no zones
are faulted (2) control panel is armed & no zones are faulted (3) control
panel is armed and any zone is faulted. Output is deactivated (off) when
control panel is disarmed & any zone is faulted. Output is deactivated
even if the zone became faulted when control panel was armed.
Activates if zone is faulted at the end of Exit Delay or if a Bad Set
condition occurs. Resets when the system is disarmed.
Activates on 60 Hz. Deactivates on 50 Hz.
Activates for approximately 0.5 sec at the start of any dialing attempt.
Use to bring up dial tone in ground start phone systems.
These 15 output functions activate for any fault on any zone assigned to
the specified Zone Function.
to
Activated/deactivated by Change Outputs function ([#][5][4]).
These 15 output functions activate for alarms on any zone assigned to
the specified Zone Function and the area(s) the output is assigned to.
to
They reset when none of the zones assigned to the specified Zone
Function are in alarm.
Activated/deactivated by Change Outputs function ([#][5][4]).
Description
EN | 91