DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
Keypad #/Door Access Control Module (DACM) Area Options
Address:
Keypad/DACM 1: 0679
-
Keypad/DACM 2: 0681
-
Keypad/DACM 3: 0683
-
Keypad/DACM 4: 0685
-
Keypad/DACM 5: 0687
-
Keypad/DACM 6: 0689
-
Keypad/DACM 7: 0691
-
Keypad/DACM 8: 0693
-
Default:
Keypad/DACM 1: 1 (Device is a keypad/DACM assigned to Area 1)
-
Keypads/DACMs 2 to 8: 0 (No keypad/DACM assigned)
-
Selections: 0 to 4, 9 to 12
Keypad/DACM Area Options
Keypad/DACM not assigned (disabled)
Assign Keypad/DACM to Area 1
Assign Keypad/DACM to Area 2
Assign Keypad/DACM to Area 3 (DS7240V2
only)
Assign Keypad/DACM to Area 4 (DS7240V2
only)
Device is a Keypad
Device is a DACM
Assign only one area to each keypad. Users (PINs) can be assigned to multiple areas. The Move to
Area function ([#][5][0]) allows users (PINs) assigned to multiple areas to view those areas from one
keypad.
The control panel supervises the connection to the DACM. If it fails to communicate with the control
panel, the control panel sends a "Dbus Missing" {125} report.
Refer to the documentation supplied with the DACM for complete installation, programming,
addressing, and operation instructions.
The control panel supports up to 8 DACMs. However, each DACM added to the system
replaces one keypad. If 8 DACMs are added, you cannot add a keypad. For full system
control, make sure at least one text keypad is included in the system.