DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
Function, Output ##
Address: See Table 33
Default:
PO 1: 1|10 Alarm: Controlled and 24-hr Zones (Fire and Non-Fire)
-
PO 2: 1|6 Strobe
-
PO 3: 0|1 Armed: All, Perimeter Only, or Partial On
-
PO 4: 2|13 Ready to Arm
-
PO 5 to PO 20: 0|0 Disabled
-
Selections: 0,0 to 8,15 (see Table 34)
This parameter assigns each output to a specific function. The function determines when the output
activates. The Mode, Time and Multiplier parameters, in combination with this Function parameter,
determine when the output deactivates.
All output functions can be reset using [#][5][4] except Alarm Outputs that follow Function Types 1|8
to 1|12, 2|11, 8|8, and those functions that can be reset by pressing [System Reset].
Table 34:
Output Function Types
Digit
Digit
1
2
0
0
Disabled
0
1
Armed – All, Perimeter Only, or
Partial On
0
2
Armed – Perimeter Only or
Partial On
0
3
Armed – All
0
4
Auto Arm Alert
0
5
Exit Delay or Entry Delay
0
6
Exit Delay
0
7
Exit Delay Finished (until
disarmed)
0
8
Armed with Ack
0
9
Entry Delay
0
10
Entry Delay + Chime
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Function Type
Output activates when the system is armed All On, Perimeter Only, or
Partial On. For Steady or Pulse modes, the output remains activated until
the system is turned off.
Output activates when the system is armed Perimeter Only, or Partial
On. For Steady or Pulse modes, the output remains activated until the
system is turned off, or moved to another armed state.
Output activates when the system is turned All On. For Steady or Pulse
modes, the output remains activated until the system is turned off, or
moved to another armed state.
Output activates at the start of the Auto Arm Alert. For Steady or Pulse
modes, the output remains activated for the duration of the alert. See
"Auto On Alert Time" in the DS7200V2 Expert Programming Guide
(P/N: 4998153891).
Output activates at the start of Exit Delay or Entry Delay. For Steady or
Pulse modes, the output remains activated until entry or exit delay ends.
Output activates at the start of Exit Delay. For Steady or Pulse modes,
the output remains activated until exit delay ends.
Output activates at the end of Exit Delay. For Steady or Pulse modes, the
output remains activated until the system is disarmed.
For systems programmed for closing reports, the output activates when
the acknowledgement for the closing report is received. For systems not
sending closing reports, the output activates at the end of Exit Delay. For
Steady or Pulse modes, the output remains activated until the system is
disarmed.
Output activates at the start of Entry Delay. For Steady or Pulse modes
the output remains activated until Entry Delay ends.
Output activates at the start of Entry Delay. For Steady or Pulse modes,
the output remains activated until entry delay ends. The output also
activates whenever a Chime zone is faulted. The output does not
activate on Chime if Chime Tone is turned off.