DS7200V2-EXP | Installation Guide | 4. Reference Materials
Table 40:
Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
14
Cross,24hr Burg
15
Cross,Cntrl,Dly
16
Cross,Cntrl
17
Cross,Unverified
18
Alarm Exit Error
19
Alrm Recent Clse
20
Alrm Recent Clse
21
Auto On Extended
22
Battery Low
23
Battery Missing
24
Rstrl Batt Low
25
Rstrl Bat Missng
26
Bypass,Fire,User
27
Bypass,Fire,
RPS
28
Bypass,Ctrl,User
29
Bypass,Ctrl, RPS
30
Bypass,24hr,User
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
SIA Report
Contact ID
Report
BM Burglary
133 24 Hr Safe
Alarm Cross Zone
BM Burglary
134 Entry/Exit
Alarm Cross Zone
BM Burglary
130 Burglary
Alarm Cross Zone
BG Unverified
378 Cross-zone
Event Burglary
Trouble
EA Exit Alarm
374 Exit Error
(zone)
CR Recent
134 Entry/Exit
Closing
CR Recent
130 Burglary
Closing
CE Closing
464 Auto-arm
Extend
Time Extended
YT System Battery
302 Low
Trouble
System Battery
YM System
311 Battery
Battery Missing
Missing/Dead
YR System
302 Low
Battery Restoral
System Battery
YR System
311 Battery
Battery Restoral
Missing/Dead
FB Fire Bypass
571 Fire
bypass
FB Fire Bypass
571 Fire
bypass
BB Burglary
570
Bypass
Zone/Sensor
bypass
BB Burglary
570
Bypass
Zone/Sensor
bypass
BB Burglary
572 24-Hr Zone
Bypass
Bypass
Event Description
Alarm, Burglary Zone Type with
Cross Zone Option selected
Alarm, Delay 1 or Delay 2 Zone
Type with Cross Zone Option
selected.
Alarm, Follower or Instant Zone
Types with Cross Zone Option
selected.
A fault on one non-fire zone type
with the Cross Zone Option
selected. This is not an alarm
event.
Zone faulted at the end of Exit
Delay.
Alarm event within 2 min. of
closing.
Alarm event within 2 min. of
closing.
Auto On Sked delayed one hour by
user. Report follows Open/Close
routing.
Panel battery is low.
Panel battery is missing. Very low,
shorted, or open batteries are
reported as missing.
Battery restoral from low battery.
Battery Restoral from missing
battery.
Selective bypass by user, fire zone
types.
Selective bypass by RPS, fire zone
types.
Selective bypass by user,
controlled zone types.
Selective bypass by RPS, zone
types.
Selective bypass by user, 24-hour
non-fire zone types.
EN | 110
Zone Types
RPS
Linked to
Event
Event
Group
8- Burglary
3
11- E/E Delay 1
3
12- E/E Delay 2
13- Follower
3
14- Instant
any with Cross
3
Zone Option
11- E/E Delay 1
3
12- E/E Delay 2
11- E/E Delay 1
3
12- E/E Delay 2
10- Keyswitch
3
13- Follower
14- Instant
10
12
12
12
12
1- Fire
15
2- Fire with
Alarm
Verification
1- Fire
2- Fire with
Alarm
Verification
10 to 15- Zone
15
Types
10 to 15- Zone
Types
3 to 9- 24-hour,
15
Non-Fire Zone
Types
Status
Report
R
S
R
S
R
S
R
S

Hide quick links: