DS7200V2-EXP | Installation Guide | 1. Introduction
1.3

Specifications

Table 2: Control Panel Specifications

Environmental Specifications
Temperature
Relative Humidity
Voltage Input to Control Panel
Primary
Secondary
Power Outputs
Continuous Power
Alarm Power
Minimum
Operating Voltage
Data Bus
Keypads
Maximum Number
per System
Compatible
Keypads
1.4

Standard Features

1.4.1
Communicator
The control panel uses a built-in digital
communicator to send reports to the receiver. It
can send reports in Contact ID, SIA 300, SIA 300
with Text, Personal Dialing Format, and Basic
Pager Format.
1.4.2
Zones
The DS7240V2 supports up to 40 zones using on-
board and off-board (including input expanders
and wireless devices). The DS7240V2 supports
up to 5 DX2010 Input Expanders.
The DS7220V2 supports up to 24 zones using on-
board and off-board (including input expanders
and wireless devices). The DS7220V2 supports
up to 3 DX2010 Input Expanders.
On-board sensor loops are marked L-1 to L-8 on
both control panel types.
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
+32°F to +122°F (0°C to +50°C)
5 to 85% at 86°F (30°C) non-
condensing
18 VAC, 50 VA
Sealed lead acid rechargeable
battery
(12 VDC, 7 Ah or 18 Ah).
Up to 1.2 A at 12 VDC nominal
(continuous supply) total for all
devices and outputs.
1.85 A for fire and combined
fire/burglary. Applies to all four
outputs combined.
10.2 VDC
12 VDC nominal. 305 m of 0.8 mm
(#22 AWG) cable
8
DS7445i or DS7445V2 LED
Keypad; DS7447E or DS7447V2
Text Keypad; DS7446KP Keypad
1.4.3
Areas and Accounts
The DS7240V2 supports up to 4 independent
areas. The DS7220V2 supports up to 2
independent areas.
All zones can be assigned to a single area, or
spread out over the available areas.
Users arm and disarm the control panel by area,
and can arm and disarm several areas with one
function. The installer can assign an authority
level to a PIN that allows a user to arm an area
from a remote keypad in another area.
Assigning each area its own account number
creates separate accounts in one control panel.
Assigning the same account number to different
areas groups them together into one account.
Area options include exit tone and delay,
separate fire and burglary outputs and auto
opening and closing Skeds (see Sked Parameters
on page 96 for more information).
Area 1 can be programmed as a "common" area.
See Arming Options 2 on page 63.
A "First to Open, Last to Close" arming option is
available (see Arming Options 2 on page 63).
1.4.4
Programmable Outputs
Four on-board programmable outputs (PO 1 to
PO 4) are available on both control panels.
The DS7240V2 supports up to 20 programmable
outputs (4 on-board, 16 off-board using two
DX3010 Output Expanders).
The DS7220V2 supports up to 12 programmable
outputs (4 on-board, 8 off-board using one
DX3010 Output Expander).
See On-board Output Setup on page 21 and Off-
board Output Setup (DX3010) on page 29.
1.4.5
Users
The control panel allows up to 32 individual
users. Each user is assigned a Personal
Identification Number (PIN) and an authority
level. Authority levels determine which functions
users can perform.
1.4.6
Keyswitch
Users can arm and/or disarm any available area
with maintained or momentary closure devices
such as keyswitches. Zone programming
determines the keyswitch's operation.
EN | 8