DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
3.2.3
Phone and RPS Configuration
Use the parameters in this section to configure the telephone and Remote Programming Software
(RPS) features.
Phone Line Options
Address: 0131
Default: 0
Selections: 0 to 3, 8 to 11
Phone Line Options
No Phone Line Options
Do Not Wait for Dial Tone
"R" Function/Three-way Calling
Reserved
Phone Line Fault Requires Reset
This parameter consists of three options for the physical phone line.
Do Not Wait for Dial Tone: If this option is enabled, the control panel waits three sec after going
off-hook and then starts dialing. If this option is disabled, the control panel waits up to seven sec
for a dial tone. The control panel dials when it detects the dial tone.
"R" Function/Three-way Calling: If this option is enabled, the control panel's "R" function/three-
way calling feature is enabled. The phone company must enable this feature on the control panel's
telephone line.
Phone Line Fault Requires Reset: If this option is enabled and a phone line fault occurs, the
trouble condition (keypad trouble message and/or tone) continues until the [System Reset] key is
pressed (fix the phone line fault first). If this option is disabled and a phone line fault occurs, the
trouble condition clears automatically when the phone line fault is corrected. This option also
applies to the Alternate Communication Path Fault Control Input. See "24-Hour Control Input Zone
Function Types" in the DS7200V2 Expert Programming Guide (P/N: 4998153891) for more
information.
Remote Programming Call Back Number
Address: 0181 to 0212
Default: All zeroes (0)
Selections: See Table 22
The control panel dials this phone number or IP address to begin a RPS remote programming session.
See Network Communication on page 101 for complete network communication programming
instructions. Firmware revision 2.10 or greater is required for network communication.
There are three ways to use this phone number (or IP address):
1. RPS calls the control panel, which answers and determines it is RPS calling, then it hangs up and
calls RPS back.
2. When a user presses [#][4][3], the control panel calls RPS using the phone number (or IP
address) entered here.
3. The control panel can be programmed to call this phone number (or IP address) automatically at
test report time (see Automatic Test {137} Report Options on page 60 for more information).
When entering phone numbers, use "10" ([1][0] from the keypad) to dial "0"; enter "0" to
terminate the phone number. This does not apply when entering an IP address.
Bosch Security Systems, Inc. | 04/12 | F01U253045-02