2.18 Always Force Arm - Bosch DS7200V2-EXP Installation Manual

Table of Contents

Advertisement

DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup

2.18 Always Force Arm

Trouble or tamper conditions can prevent the
control panel from arming. Enter the following
special command sequence force arms the
control panel:
1. If an arming sequence is entered and a
condition prevents arming, the keypad
sounds an error tone.
2. Enter the arming sequence again as if to force
arm the area. The keypad sounds a second
error tone.
3. Press [#][9]. The control panel checks if a
valid PIN was already entered. If not, it
prompts for a valid PIN.
4. Enter a valid PIN. The control panel force
arms any off-normal zones.
Any pre-existing trouble conditions that would
have caused an alarm when armed do not cause
an alarm. The keypad indicates that a system
trouble exists.
The sequence described above must be followed
exactly as described. If more than 10 sec passes
between the key presses, the sequence is
broken.
This information is intentionally not
included in the DS7200V2 User's
Guide (P/N 4998153894).
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
EN | 48